Shrnutí obsahu

Strany 1 - 1794-SG002D-EN-P

FLEX I/O, FLEX I/O XT, and FLEX ExBulletin 1794 and 17971794-SG002D-EN-P

Strany 2 - Important User Information

Publication 1794-SG002D-EN-P - May 20122 About the FLEX I/O and FLEX Ex I/O SystemsTerminal bases can be exchanged without moving other bases i

Strany 3 - Table of Contents

Publication 1794-SG002D-EN-P - May 201292 Select FLEX Ex I/O ModulesModule SpecificationsThe following section shows more detailed module speci

Strany 4

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 93Schematic Drawing of the 1797-IE8 Module FLEX Ex Analog Input ComparisonSpe

Strany 5 - Table of Contents v

Publication 1794-SG002D-EN-P - May 201294 Select FLEX Ex I/O Modules1797-IRT8 8 Point 16-bit Non-isolated RTD Thermocouple/mV Input Module• inp

Strany 6 - Section 4.1

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 95HART Interface ModulesFLEX Ex HART analog modules (1797-IE8H and 1797-OE8H)

Strany 7 - Information

Publication 1794-SG002D-EN-P - May 201296 Select FLEX Ex I/O ModulesFLEX Ex I/O Analog Output Modules1797-OE8 and 1797-OE8H (HART) 8 Point 13-b

Strany 8

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 971797-OE8 Output Voltage/Current CapabilityTransfer characteristics, accurac

Strany 9 - 1794 FLEX I/O Overview

Publication 1794-SG002D-EN-P - May 201298 Select FLEX Ex I/O Modules1797-OE8H Output Voltage/Current CapabilityCounter I/O ModuleIdeal for appl

Strany 10

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 99• Calculate frequency on time interval or input count• Programmable scaling

Strany 11 - 1794 FLEX I/O XT Overview

Publication 1794-SG002D-EN-P - May 2012100 Select FLEX Ex I/O ModulesInput frequency range 1.0…32,767 HzFrequency resolution, min Sampling Time

Strany 12

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 101Notes:

Strany 13 - FLEX I/O XT System

Publication 1794-SG002D-EN-P - May 2012About the FLEX I/O and FLEX Ex I/O Systems 31794 FLEX I/O XT OverviewFLEX I/O XT modules are designated

Strany 14

Publication 1794-SG002D-EN-P - May 2012102 Select FLEX Ex I/O Modules

Strany 15 - CIP Network Infrastructure

103 Publication 1794-SG002D-EN-P - May 2012Section 2.4Select a FLEX Ex I/O Terminal Base UnitStep 3 – Select:the appropriate terminal base unit for yo

Strany 16 - Select a Network

Publication 1794-SG002D-EN-P - May 2012104 Select a FLEX Ex I/O Terminal Base UnitWiring when total module current draw is greater than 8.5 WCo

Strany 17 - Device-Level Ring Topology

105 Publication 1794-SG002D-EN-P - May 2012Section 2.5Select a FLEX Ex I/O Power SupplyStep 4 – Select:if power consumption exceeds the maximum for a

Strany 18 - ControlNet Network

Publication 1794-SG002D-EN-P - May 2012106 Select a FLEX Ex I/O Power SupplyE Type Power SupplyN Type Power SupplyUnderstanding System Planning

Strany 19 - DeviceNet Network

Publication 1794-SG002D-EN-P - May 2012Select a FLEX Ex I/O Power Supply 107The total number of power supplies needed depends on the modules us

Strany 20 - DNet In DNet Out

Publication 1794-SG002D-EN-P - May 2012108 Select a FLEX Ex I/O Power SupplyAssigning Power SuppliesNote the amount of power each module requir

Strany 21 - Other Network Communication

Publication 1794-SG002D-EN-P - May 2012Select a FLEX Ex I/O Power Supply 109Hazardous Area InstallationThe following illustration provides an e

Strany 22 - Other Networks – PROFIBUS DP

Publication 1794-SG002D-EN-P - May 2012110 Select a FLEX Ex I/O Power Supply1797-PS1N and 1797-PS1E 85V…253V AC In/Quad-Ex DC OutType of Power

Strany 23 - Select FLEX I/O Modules

Publication 1794-SG002D-EN-P - May 2012Select a FLEX Ex I/O Power Supply 111Input power entry 1 in NPT, ≤ 6 in conduit allowed between power su

Strany 24 - Digital I/O Module Summary

Publication 1794-SG002D-EN-P - May 20124 About the FLEX I/O and FLEX Ex I/O SystemsCertifications (when product is marked)(3)• UL Listed Indust

Strany 25

Publication 1794-SG002D-EN-P - May 2012112 Select a FLEX Ex I/O Power SupplyNotes:

Strany 26 - Digital Modules

113 Publication 1794-SG002D-EN-P - May 2012Section 3.1Mount the FLEX SystemStep 6 – Select:•panel mount or DIN rail mount•appropriate number of panels

Strany 27 - Derating Curve

Publication 1794-SG002D-EN-P - May 2012114 Mount the FLEX SystemWhen properly installed, FLEX I/O and FLEX Ex I/O are grounded through the DIN

Strany 28 - Modules Specifications

115 Publication 1794-SG002D-EN-P - May 2012Section 3.2Select Optional AccessoriesStep 5 – Select:optional accessories for FLEX I/O and FLEX I/O XT mod

Strany 29 - Digital AC Output Comparison

Publication 1794-SG002D-EN-P - May 2012116 Select Optional Accessories1492-EA35 DIN Rail LocksWhen you use FLEX I/O modules in a high-vibration

Strany 30

Publication 1794-SG002D-EN-P - May 2012Select Optional Accessories 117Step 5 – Select:optional accessories for FLEX Ex I/O modules1797-BOOT Con

Strany 31 - Digital DC Input Comparison

Publication 1794-SG002D-EN-P - May 2012118 Select Optional AccessoriesControlNet Ex Taps1797-TPS ControlNet Ex Straight T-Tap1797-TPR ControlNe

Strany 32

Publication 1794-SG002D-EN-P - May 2012Select Optional Accessories 1191797-XT ControlNet Ex 75Ω TerminatorThe terminator is sold in lots of 50.

Strany 33 - 1794-IC16 Derating Curve

Publication 1794-SG002D-EN-P - May 2012120 Select Optional AccessoriesNotes:

Strany 34 - Digital DC Output Comparison

121 Publication 1794-SG002D-EN-P - May 2012Section 4.1Related DocumentationFLEX I/O and FLEX I/O XTAdditional user documentation presents information

Strany 35

Publication 1794-SG002D-EN-P - May 2012About the FLEX I/O and FLEX Ex I/O Systems 5Specify a FLEX I/O or FLEX I/O XT SystemFollow these steps a

Strany 36 - 1794-OB16P Derating Curve

Publication 1794-SG002D-EN-P - May 2012122 Related DocumentationBases 1794-TBNFK FLEX I/O D-Shell Terminal Base Units Installation Instructions

Strany 37 - Surge Current — A

Publication 1794-SG002D-EN-P - May 2012Related Documentation 123DC 1794-IV16 FLEX I/O Digital DC Sourcing Input and Sinking Output Modules Inst

Strany 38

Publication 1794-SG002D-EN-P - May 2012124 Related DocumentationAnalog 1794-OE12 FLEX I/O 12 Channel Analog Modules Installation Instructions 1

Strany 39 - 1794-IB16D Derating Curves

Publication 1794-SG002D-EN-P - May 2012Related Documentation 125FLEX Ex I/OAdditional user documentation presents information according to the

Strany 40

Publication 1794-SG002D-EN-P - May 2012126 Related DocumentationNotes:

Strany 42

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Publication 1794-SG002D-EN-P - May

Strany 43 - Thermocouple and RTD

Publication 1794-SG002D-EN-P - May 20126 About the FLEX I/O and FLEX Ex I/O SystemsNotes:

Strany 44 - Analog I/O Module Summary

7 Publication 1794-SG002D-EN-P - May 2012Section 1.2Select FLEX I/O Communication AdaptersStep 1 – Select:a communication adapter based on the appropr

Strany 45

Publication 1794-SG002D-EN-P - May 20128 Select FLEX I/O Communication AdaptersSelect a NetworkYou can configure your system for information ex

Strany 46

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Communication Adapters 9Figure 1 - EtherNet/IP Communication Device-Level Ring TopologyA

Strany 47 - Analog 12 Input Module

Publication 1794-SG002D-EN-P - May 201210 Select FLEX I/O Communication AdaptersDLR network using EtherNet/IP taps. The following is an illustr

Strany 48 - Isolated Analog Input Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Communication Adapters 11DeviceNet NetworkThe DeviceNet network is an open low-level net

Strany 49

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strany 50

Publication 1794-SG002D-EN-P - May 201212 Select FLEX I/O Communication AdaptersDeviceNet Communication Other Networks – Remote I/OThe 1794-ASB

Strany 51 - 1794-IR8 RTD Input Module

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Communication Adapters 13The 1794-ASB2 supports only two FLEX I/O modules. The 1794-ASBL

Strany 52 - 1794-IR8 Derating Curve

Publication 1794-SG002D-EN-P - May 201214 Select FLEX I/O Communication AdaptersOther Networks – PROFIBUS DPUse the 1794-APB or 1794-APBDPV1 ad

Strany 53

15 Publication 1794-SG002D-EN-P - May 2012Section 1.3Select FLEX I/O ModulesStep 2 – Select:I/O modulesThe FLEX I/O module plugs into the terminal bas

Strany 54 - Thermocouple/mV Input Module

Publication 1794-SG002D-EN-P - May 201216 Select FLEX I/O Modules120V AC: Input/Output and Isolated Input/Output, 8 and 16 point220V AC: Input/

Strany 55 - = Safe operating area

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 17DC Modules1794-IB8 8 — 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK24V DC Noniso

Strany 56

Publication 1794-SG002D-EN-P - May 201218 Select FLEX I/O ModulesSelect Input Filter Times for Digital ModulesInput filter times can be set to

Strany 57 - Combination Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 19Derating CurveThe area within the curve represents the safe operating range fo

Strany 58 - Analog Combination Module

Publication 1794-SG002D-EN-P - May 201220 Select FLEX I/O ModulesModules SpecificationsThe following section shows more detailed module specifi

Strany 59 - Analog Output Comparison

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 211794-IM8 Derating CurveThe area within the curve represents the safe operating

Strany 60 - Analog 4 Input Modules

iii Publication 1794-SG002D-EN-P - May 2012Table of ContentsSummary of ChangesNew and Updated Information. . . . . . . . . . . . . . . . . . . . . . .

Strany 61

Publication 1794-SG002D-EN-P - May 201222 Select FLEX I/O Modules1794-OA16 Derating CurveThe area within the curve represents the safe operatin

Strany 62 - Analog 12 Output Module

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 231794-OM8 Derating CurveThe area within the curve represents the safe operating

Strany 63

Publication 1794-SG002D-EN-P - May 201224 Select FLEX I/O Modules1794-IB16 Derating CurveThe area within the curve represents the safe operatin

Strany 64

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 251794-IB32 Derating CurveThe area within the curve represents the safe operatin

Strany 65

Publication 1794-SG002D-EN-P - May 201226 Select FLEX I/O ModulesFLEX I/O Digital DC Output Modules• 1794-OB8 and 1794-OB16 provide 16 sourcing

Strany 66 - FLEX I/O Counter Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 27FLEX I/O Digital DC Protected Output Modules• 1794-OB16P provides 16 sourcing

Strany 67

Publication 1794-SG002D-EN-P - May 201228 Select FLEX I/O Modules1794-OB16P Derating CurveThe area within the curve represents the safe operati

Strany 68 - 24V DC Input Frequency Module

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 291794-OB8EP Output Minimum SurgeFLEX I/O Digital DC Diagnostic Modules1794-IB16

Strany 69

Publication 1794-SG002D-EN-P - May 201230 Select FLEX I/O ModulesCurrent, sensor source, max 50 mADimensions (HxWxD), approx 46 x 94 x 53 mm (1

Strany 70

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 311794-IB16D Derating CurvesAmbient Temperature °CInput Voltage (V)Input Voltage

Strany 71 - 2 Input Pulse Counter Module

Publication 1794-SG002D-EN-P - May 2012iv Table of Contents 1794-IT8 Thermocouple/mV Input Module . . . . . . . . . . . . . . . . . . . 46179

Strany 72 - 4 Input Pulse Counter Module

Publication 1794-SG002D-EN-P - May 201232 Select FLEX I/O ModulesFLEX I/O Digital DC Combination ModulesThe 1794-IB16XOB16P module has outputs

Strany 73

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 33FLEX I/O Digital Contact Output Modules (Relay)The 1794-OW8 module provides 8

Strany 74

Publication 1794-SG002D-EN-P - May 201234 Select FLEX I/O ModulesThe 1794-OW8XT module is the extended temperature version of the 1794-OW8 modu

Strany 75

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 35FLEX I/O Analog, Thermocouple and RTD ModulesChoose analog, thermocouple, or R

Strany 76

Publication 1794-SG002D-EN-P - May 201236 Select FLEX I/O ModulesAnalog I/O Module SummaryCatalog Number Inputs Outputs Terminal Base Unit Modu

Strany 77 - 1794-PS13 AC/DC

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 37Modules SpecificationsThe following section shows more detailed module specifi

Strany 78

Publication 1794-SG002D-EN-P - May 201238 Select FLEX I/O Modules1794-IE8 and 1794-IE8XT Analog 8 Input ModuleThe 1794-IE8 is a voltage/current

Strany 79 - About the FLEX Ex I/O Systems

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 391794-IE8H HART Enabled Analog 8 Input ModuleThe 1794-IE8H is a HART enabled an

Strany 80

Publication 1794-SG002D-EN-P - May 201240 Select FLEX I/O Modules1794-IF4I and 1794-IF4IXT Isolated Analog 4 Input ModuleThe 1794-IF4I and 1794

Strany 81 - Configurations

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 41Input resolution 16 bits – unipolar15 bits + sign – bipolar0.320 μA/cnt – unip

Strany 82

Publication 1794-SG002D-EN-P - May 2012Table of Contents vSection 2.2Select FLEX Ex I/O Communication Adapters and Distribution Method1797-RP

Strany 83 - Designation

Publication 1794-SG002D-EN-P - May 201242 Select FLEX I/O Modules1794-IF8IH HART Enabled Analog 8 Input ModuleThe 1794-IF8IH accepts up to 8 an

Strany 84

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 431794-IR8 RTD Input ModuleThe 1794-IR8 is a temperature-measuring module that a

Strany 85

Publication 1794-SG002D-EN-P - May 201244 Select FLEX I/O Modules1794-IR8 Derating CurveThe area within the curve represents the safe operating

Strany 86 - Specify a FLEX Ex System

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 45Thermocouple/RTD Input Module Specification 1794-IRT8 and 1794-IRT8XTInput res

Strany 87

Publication 1794-SG002D-EN-P - May 201246 Select FLEX I/O Modules1794-IT8 Thermocouple/mV Input ModuleThe 1794-IT8 module is a temperature/mV m

Strany 88

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 471794-IRT8 Derating CurveThe area within the curve represents the safe operatin

Strany 89

Publication 1794-SG002D-EN-P - May 201248 Select FLEX I/O Modules1794-IE8XOE4 8 Input/4 Output Analog Combination ModuleThe 1794-IE8XOE4 is a c

Strany 90 - 1797-BCNR Coax Barrier Module

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 491794-IE4XOE2 and 1794-IE4XOE2XT 4 Input/2 Output Analog Combination ModulesThe

Strany 91

Publication 1794-SG002D-EN-P - May 201250 Select FLEX I/O Modules1794-IF2XOF2I and 1794-IF2XOF2IXT 2 Input/2 Output Isolated Analog Combination

Strany 92

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 51FLEX I/O Analog Output ModulesNormal mode rejection ratio -3 dB @ 12 Hz (300 H

Strany 93

Publication 1794-SG002D-EN-P - May 2012vi Table of Contents 1797-PS2N2 and 1797-PS2E2 24V DC In/Quad-Ex DC Out . . . . . . . . . . . . . . . .

Strany 94

Publication 1794-SG002D-EN-P - May 201252 Select FLEX I/O Modules1794-OE4 and 1794-OE4XT Analog 4 Output ModuleThe 1794-OE4 module has 4 output

Strany 95 - Select FLEX Ex I/O Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 531794-OE8H HART Enabled Analog 8 Output ModuleThe 1794-OE8H is a HART enabled a

Strany 96

Publication 1794-SG002D-EN-P - May 201254 Select FLEX I/O Modules1794-OE12 Analog 12 Output Module1794-OE12 module is a High Density analog out

Strany 97 - (2) 1 ms default selectable

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 551794-OF4I and 1794-OF4IXT Isolated Analog 4 Output ModuleThe 1794-OF4I modules

Strany 98

Publication 1794-SG002D-EN-P - May 201256 Select FLEX I/O Modules1794-OF8IH HART Isolated Analog 8 Output ModuleThe 1794-OF8IH modules provides

Strany 99 - Analog Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 57Thermal dissipation, max 16 BTU/hr @ 31.2V DCWire size 0.34... 2.5 mm2 (22...1

Strany 100 - Module Specifications

Publication 1794-SG002D-EN-P - May 201258 Select FLEX I/O ModulesFLEX I/O Counter ModulesIn order to decide which FLEX I/O counter module would

Strany 101

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 591794-IJ2 and 1794-IJ2XT 24V DC Input Frequency ModuleThe 1794-IJ2 is essential

Strany 102 - Input Module

Publication 1794-SG002D-EN-P - May 201260 Select FLEX I/O ModulesThe frequency input module isolated power supply consists of 1 isolated 24V DC

Strany 103 - HART Interface Modules

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 611794-VHSC 2 Channel Very High Speed Counter ModuleA counter module has two inc

Strany 104 - Output Modules

Publication 1794-SG002D-EN-P - May 2012Summary of ChangesThis manual contains new and updated information. Changes throughout this revision are marked

Strany 105

Publication 1794-SG002D-EN-P - May 201262 Select FLEX I/O Modules1794-VHSC Derating CurveThe area within the curve represents the safe operatin

Strany 106 - Counter I/O Module

Publication 1794-SG002D-EN-P - May 2012Select FLEX I/O Modules 631794-ID2 2 Input Pulse Counter ModuleThe 1794-ID2 module is a 2-channel counte

Strany 107

Publication 1794-SG002D-EN-P - May 201264 Select FLEX I/O Modules1794-IP4 4 Input Pulse Counter ModuleThe pulse counter modules perform high-sp

Strany 108

65 Publication 1794-SG002D-EN-P - May 2012Section 1.4Select a FLEX I/O Terminal Base UnitStep 3 – Select:the appropriate terminal base unit for your m

Strany 109

Publication 1794-SG002D-EN-P - May 201266 Select a FLEX I/O Terminal Base Unit1794-TB3T Cage clamp, temperature16 I/O; 10 common; 4 +V; 8 chass

Strany 110

67 Publication 1794-SG002D-EN-P - May 2012Section 1.5Select a FLEX I/O Power SupplyStep 4 – Select:if power consumption exceeds the maximum for a sing

Strany 111 - Diagrams

Publication 1794-SG002D-EN-P - May 201268 Select a FLEX I/O Power SupplyThe 1606 switched mode power supplies are capable of supplying a maximu

Strany 112

Publication 1794-SG002D-EN-P - May 2012Select a FLEX I/O Power Supply 691794-PS3 AC/DC1794-PS13 AC/DCoutput current loadreal power (Wattsappare

Strany 113 - Step 4 – Select:

Publication 1794-SG002D-EN-P - May 201270 Select a FLEX I/O Power SupplyNotes:

Strany 114 - Understanding System Planning

71 Publication 1794-SG002D-EN-P - May 2012Section 2.1About the FLEX Ex I/O Systems1797 FLEX Ex I/O OverviewFLEX Ex I/O offer:FLEX Ex I/O leverages adv

Strany 115

Publication 1794-SG002D-EN-P - May 2012viii Summary of ChangesAnalog I/O Modules1794-IE8XT 371794-IF4IXT 371794-IF4ICFXT 371794-IF8IH 371794-IR

Strany 116 - Assigning Power Supplies

Publication 1794-SG002D-EN-P - May 201272 About the FLEX Ex I/O SystemsPlug the I/O module into the terminal base. Use the module to connect to

Strany 117 - Hardened conduit

Publication 1794-SG002D-EN-P - May 2012About the FLEX Ex I/O Systems 73FLEX Ex Typical ConfigurationsThe following are typical configurations o

Strany 118 - Type of Power Input

Publication 1794-SG002D-EN-P - May 201274 About the FLEX Ex I/O Systems

Strany 119

Publication 1794-SG002D-EN-P - May 2012About the FLEX Ex I/O Systems 75Entity-Based ArchitectureEntity parameters provide a system of quantifyi

Strany 120

Publication 1794-SG002D-EN-P - May 201276 About the FLEX Ex I/O SystemsUse in North American Hazardous LocationsFLEX Ex modules are rated for i

Strany 121 - Mount the FLEX System

Publication 1794-SG002D-EN-P - May 2012About the FLEX Ex I/O Systems 77As always, observe local code requirements when applying your FLEX Ex ap

Strany 122

Publication 1794-SG002D-EN-P - May 201278 About the FLEX Ex I/O SystemsSpecify a FLEX Ex SystemFollow these steps as you specify your FLEX Ex I

Strany 123 - Select Optional Accessories

79 Publication 1794-SG002D-EN-P - May 2012Section 2.2Select FLEX Ex I/O Communication Adapters and Distribution MethodStep 1 – Select:the communicatio

Strany 124 - 1794-CJC2

Publication 1794-SG002D-EN-P - May 201280 Select FLEX Ex I/O Communication Adapters and Distribution MethodFigure 1 - Distribution Between Area

Strany 125 - Step 5 – Select:

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Communication Adapters and Distribution Method 811797-ACNR15 Dual Media ControlNet Ex

Strany 126 - ControlNet Ex Taps

1 Publication 1794-SG002D-EN-P - May 2012Section 1.1About the FLEX I/O and FLEX Ex I/O Systems1794 FLEX I/O OverviewFLEX I/O offers:FLEX I/O is a Dist

Strany 127 - 1786-RG6 Coax Trunk Cable

Publication 1794-SG002D-EN-P - May 201282 Select FLEX Ex I/O Communication Adapters and Distribution Method1797-RPFM ControlNet Ex 3 km Fiber M

Strany 128

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Communication Adapters and Distribution Method 83FLEX I/O Remote I/O Adapter Specific

Strany 129 - Related Documentation

Publication 1794-SG002D-EN-P - May 201284 Select FLEX Ex I/O Communication Adapters and Distribution Method1797-BIC Bus Isolator Module and 179

Strany 130

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Communication Adapters and Distribution Method 85When combining 1794 FLEX I/O and 179

Strany 131

Publication 1794-SG002D-EN-P - May 201286 Select FLEX Ex I/O Communication Adapters and Distribution MethodNotes:

Strany 132

87 Publication 1794-SG002D-EN-P - May 2012Section 2.3Select FLEX Ex I/O ModulesStep 2 – Select:I/O modules based on field devicesFLEX Ex follows a pro

Strany 133 - For More Information

Publication 1794-SG002D-EN-P - May 201288 Select FLEX Ex I/O ModulesModules SpecificationsThe following section shows more detailed module spec

Strany 134

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 891797-OB4D 24V DC 4 Point Non-isolated Source Output Module• 4 output channe

Strany 135

Publication 1794-SG002D-EN-P - May 201290 Select FLEX Ex I/O Modules1797-OB4D Output Voltage/Current Capability24V DC 4 Point Non-isolated Sour

Strany 136 - Documentation Feedback

Publication 1794-SG002D-EN-P - May 2012Select FLEX Ex I/O Modules 91Analog ModulesChoose analog I/O modules when you need:• Configurable channe