Care of Your Mass Storage System
Appendix A
A2
humidity and corrosive vapors
Maximum Shock Without Incurring Physical Damage
Operating: 3g
Non-operating: 35g
Shock levels beyond this specification could result in loss of oxide media, head
misalignment, and/or permanent loss of all recorded data.
Maximum Vibration Without Incurring Soft Errors
Operating:
Series A Systems Series B Systems
2 to 22 Hz 5 to 12 Hz
0.010 inch double amplitude 0.010 inch double amplitude
22 to 500 Hz 12 to 250 Hz
1.0g 1.0g
Maximum Vibration Without Incurring Physical Damage
Non-operating:
Series A Systems Series B Systems
2 to 22 Hz 5 to 36 Hz
0.040 inch double amplitude 0.050 inch double amplitude
22 to 500 Hz 36 to 250 Hz
1.0g 3.0g
We test vibration two ways:
Operating: While operating, the product vibrates for a minimum of one
hour each at the X,Y, and Z axes at a rate of 15 minutes per sweep cycle over
a frequency range of 5 to 2000Hz.
Non-operating: With no power applied, the product vibrates for a minimum
of one hour each at the X,Y, and Z axes at a rate of 15 minutes per sweep
cycle over a frequency range of 5 to 2000Hz.
Dust
The Winchester disk drive of your mass storage system contains its own air
filtration system. The system permits circulation of internal air and equalization
Zobrazit stránku 41