Configure PhaseManager 109
Manually Change States
With RSLogix 5000 programming software, you can manually change an
equipment phase.
To manually change a PhaseManager state, perform this procedure.
Comparing PhaseManager
to Other State Models
You can compare PhaseManager state models to other state models.
Current Equipment Phase
1. Take ownership of the equipment phase.
2. Give a command.
State Model Comparisons
S88 PackML PhaseManager
Idle Starting Ready Resetting Idle
Running Complete Producing Running Complete
Pausing Paused Standby Subroutines or breakpoints
Holding Held Holding Held Holding Held
Restarting None Restarting
Stopping Stopped Stopping Stopped Stopping Stopped
Aborting Aborted Aborting Aborted Aborting Aborted