Rockwell Automation Publication XXXX-X.X.X - Month Year 177
Chapter 3
Network Communication
Overview
The process of migrating from a 1395, 1397, and FlexPak 3000 to a PowerFlex
DC drive can vary significantly depending on the controller type communicating
with the drive and the particular communication module installed in the drive.
This chapter describes which architecture-class (20-COMM) network options
can be used with the PowerFlex DC drives. Because of the wide variety of
networks, processors, and drive options to consider, only migration information
is presented, rather than step-by-step procedures.
Bulletin 1395 DC Drive
Network Communication
Options
The 1395 drive has the following network communication options:
• Remote I/O
• Serial
• DF1
• Data Highway Plus
• ControlNet™
1395 Node Adapter Board
The Node Adapter board provides a sophisticated interface between external
devices and the main control board. This adapter board provides the following
features:
• Capable of configuration as a Remote I/O (RIO) interface
• Compatible with Allen-Bradley PLC3 or PLC5 family of programmable
logic controllers (PLC)
Topic Page
Overview 177
Bulletin 1395 DC Drive Network Communication Options 177
Bulletin 1397 DC Drive Network Communication Options 179
FlexPak 3000 DC Drive Network Communication Options 180
PowerFlex DC Drive Network Communication Options 181
Logic Command and Status 182
Rockwell Automation Encompass Partner Migration Offerings 190
Komentáře k této Příručce